Plumbing Systems

Valve types in plumbing: what each valve does and where it goes

A clear guide to ball, gate, globe, angle, check, pressure reducing, float, thermostatic mixing and concealed valves, plus air vents.

5 min readUpdated
ForHomeownersPlumbersEngineers

Valves are the switches of a plumbing system. They let you shut off water for repairs, stop water flowing backwards, keep pressure at a safe level and fill tanks automatically. Knowing the main types helps you plan a system that is easy to maintain and helps you find the right valve quickly when something goes wrong.

Shut-off valves: ball, gate and globe

Ball valve. Inside is a ball with a hole through it. A quarter turn of the lever lines the hole up with the pipe (open) or turns it across (closed). Ball valves open and close quickly, seal well and give almost no flow restriction when fully open, so they are the most common shut-off valve in modern homes. They are meant to be either fully open or fully closed, not half open for long periods.

Gate valve. A wedge-shaped gate moves up and down as you turn the wheel. Fully open, it gives a clear path for water. It takes many turns to operate, which reduces sudden pressure shocks in large pipes, but the gate and seat can wear or jam with scale over time. Gate valves are found on older systems and larger mains.

Globe valve. Water passes through an internal seat and a disc moves towards or away from it. This design is good for regulating flow, but it causes more pressure loss than a ball valve. It is used where flow needs adjusting, for example on some heating circuits.

ValveOperationBest useFlow loss when open
Ball valveQuarter turnQuick on/off isolationVery low
Gate valveMulti-turn wheelIsolation on mains, older systemsLow
Globe valveMulti-turn wheelRegulating flowHigher

Valves at the fixture

Angle valve (stop valve). The small chrome valve under a basin, behind a toilet or for a washing machine, usually 1/2". The supply comes from the wall and the outlet turns 90 degrees to a flexible hose. It lets you isolate one fixture without shutting down the whole house. Fit one at every basin, toilet cistern and appliance.

Concealed stop valve. A valve built into the wall with only a cover and handle showing. These are often used to isolate a whole bathroom, or the hot and cold lines feeding a shower mixer. Because the valve body is hidden, choose good quality and make sure it can be serviced from the front. Concealed cisterns have their own internal stop valve; see Concealed cistern types.

Check valves and pressure reducing valves

Check valve (non-return valve). Lets water flow one way only. It is used after pumps, so water does not run back to the tank when the pump stops, and to stop hot water flowing back into cold lines. Common types are spring and swing check valves. A pump suction line from a ground tank often has a foot valve, which is a check valve with a strainer.

Pressure reducing valve (PRV). Lowers high incoming pressure to a steady, safe level for the building. It protects pipes, mixers, heaters and fittings, and is important after strong booster pumps and on the lower floors of tall buildings. A pressure gauge next to it lets you check the setting. A strainer before it keeps debris out.

Tank and temperature control valves

Float valve. The valve that fills a water tank or toilet cistern and closes automatically when the water reaches a set level. In Iraq, almost every roof tank and ground tank has one. A worn float valve is a common cause of tanks overflowing and cisterns running; see Fixing a running toilet cistern.

Thermostatic mixing valve (TMV). Mixes hot and cold water to deliver a steady, safe outlet temperature, even if the supply temperatures or pressures change. It reduces the risk of scalding, which matters with children and elderly people. It also allows the heater to store water hot enough to limit bacteria, while delivering cooler water to taps. Thermostatic shower mixers use the same idea; see Shower mixer types.

Safety valves on heaters. Water heaters and boilers need a pressure and temperature relief valve as specified by the manufacturer. Never block or remove it.

Air vents

Automatic air vent. A small valve fitted at high points of heating systems and some water lines. It releases trapped air, which otherwise causes gurgling noises, poor circulation, cold radiators and air locks. Manual bleed valves on radiators do the same job by hand.

Air is also a common cause of spluttering taps after the water supply returns. Where water is cut regularly, venting high points helps.

Choosing quality valves

  • Look for a solid brass body; see Brass vs zinc alloy.
  • Check the pressure and temperature rating printed on the valve.
  • Match the thread size to your pipe system (see Pipe types and sizes).
  • Install valves where they can be reached later, not behind tiles with no access.

To see how all these valves fit into a full system, read Water distribution systems in buildings.

You are welcome to visit the VAMO showrooms in Ranya and Erbil to see these valves in person and ask any questions.

Have a question about your project?

Call us or visit one of our showrooms. Our team will explain the options in plain words.