Toilet keeps running or leaking? How to find and fix the cause
Step-by-step troubleshooting for a running or leaking toilet cistern: fill valve, flush valve seal, float, limescale, overflow and concealed cisterns.
A toilet that keeps running wastes a lot of water, raises the load on your roof tank or pump, and can leave limescale stains in the bowl. The good news is that the cause is usually one of a few small parts inside the cistern, and many of these problems can be found in minutes. This guide works for exposed cisterns and for concealed cisterns behind a flush plate.
How a cistern works
Every cistern has two main valves:
- The fill valve lets water in. A float rises with the water level and closes the valve when the cistern is full.
- The flush valve sits at the bottom. When you press the button, it lifts and releases water into the bowl. It then drops back and seals with a rubber washer.
- The overflow is a tube, usually part of the flush valve, that sends excess water into the bowl if the level gets too high, so the cistern never spills onto the floor or inside the wall.
A running toilet means water is passing one of these points when it should not.
Step 1: Find where the water is going
Take off the cistern lid, or remove the flush plate on a concealed cistern, and watch the water level.
| What you see | Likely cause |
|---|---|
| Water level reaches the top of the overflow and runs into it | Fill valve not closing, or float set too high |
| Water level is below the overflow but water still trickles into the bowl | Flush valve seal leaking |
| Cistern refills by itself every so often without anyone flushing | Flush valve seal leaking slowly |
| Cistern fills very slowly or not at all | Blocked fill valve filter or closed supply valve |
| Water on the floor or wall | Leak at the supply connection, the cistern-to-bowl seal or the drain connection |
Step 2: Fix a fill valve that does not shut off
- Adjust the float. Most modern fill valves have an adjustment screw or clip that sets the water level. Set it so the water stops a little below the top of the overflow, usually where a mark on the cistern shows.
- If adjusting does not help, close the supply valve, take the top off the fill valve as the maker's instructions show, and rinse out any sand, rust or scale.
- Clean the small filter screen at the inlet. Sediment from roof tanks and old pipes often blocks it.
- If the seal inside the valve is hard, cracked or worn, replace the seal or the whole fill valve. Fill valves are inexpensive and widely available.
Step 3: Fix a leaking flush valve seal
- Close the supply valve and flush to empty the cistern.
- Remove the flush valve. On many modern valves it twists or clips out without tools.
- Check the rubber seal at the bottom. Clean off limescale and dirt with a soft cloth; do not scratch the seal or the seat it sits on.
- If the seal is flattened, cracked or hard, replace it with the correct seal for that valve model.
- Refit the valve, open the water and check again with the colour test.
Also check that nothing stops the valve from closing: a chain that is too short on older cisterns, a sticking button or a flush plate rod that is set too long can hold the valve slightly open.
Limescale and hard water
Many areas of Iraq and the Kurdistan Region have hard water, which leaves white calcium deposits on valve seals, seats and moving parts. Scale stops seals from sitting flat and makes fill valves stick.
- Soak removable plastic and rubber parts in diluted white vinegar or a mild descaler, then rinse well.
- Avoid strong acids and sharp tools, which damage rubber seals and plastic parts.
- Where scale is a constant problem, a water softener or filter on the supply can extend the life of all bathroom fittings.
Concealed cisterns: working through the flush plate
The opening behind the flush plate is designed as a service hatch.
- Remove the flush plate. Most plates unclip or lift off; some have a small fixing screw or catch.
- Remove the inner actuation frame or cover, according to the brand's instructions.
- Close the isolation valve, which is usually inside the cistern near the fill valve.
- The fill valve and flush valve can then be lifted out through the opening for cleaning or replacement.
- On refitting, check that the plate's rods or buttons have a small gap and do not press on the valve. A rod set too long is a common cause of a constantly running concealed cistern.
When to call a plumber
- Water is leaking inside the wall, onto the floor or into the room below.
- You cannot find the brand or model of a concealed cistern, or the parts will not come out easily.
- The isolation valve is seized or will not close.
- The cistern itself is cracked, or the bowl connection leaks.
- The problem returns quickly after cleaning and replacing seals.
A dripping tap often has similar causes, such as worn seals and scale; see dripping faucet fix. For more on cistern designs, see concealed cistern types and flush plates.
You are welcome to visit the VAMO showrooms in Ranya and Erbil to see these products in person and ask any questions.